Rectangular Weir Discharge Calculator
English

Simplified calculator to measure the water discharge rate over a suppressed or contracted rectangle shaped weir. This is based on Francis formula.

Rectangular Weir Discharge Calculation

Head on the Weir (h) = m
Width of the Weir (b) = m
Water Flow Rate = m³/s

Simplified calculator to measure the water discharge rate over a suppressed or contracted rectangle shaped weir. This is based on Francis formula.

Code to add this calci to your website Expand embed code Minimize embed code
Formula The Francis equation is as follows     q = 3.33 ×( b - 0.2×h ) ×h3/2 Where,     q = Flow Rate     b = Width of the Weir     h = Head on the Weir

The discharge rates of open channels such as streams can be measured using this rectangular weir calculator.


english Calculators and Converters