Formula:
T / T* = 1 / [(2 / (γ + 1)) * (1 + ((γ - 1) / 2) * M2)]
Where,
T / T* = Fanno Flow Temperature Ratio
T = Temperature
T* = Temperature with Throat location
M = Mach Number
γ = Heat Capacity Ratio
Formula:
P / P* = (1 / M) * (1 / √((2 / (γ + 1)) * (1 + ((γ - 1) / 2) * M2)))
Where,
P / P* = Fanno Flow Pressure Ratio
P = Pressure
P* = Pressure with Throat location
Formula:
ρ / ρ* = (1 / M) * √((2 / (γ + 1)) * (1 + ((γ - 1) / 2) * M2))
Where,
ρ / ρ* = Fanno Flow Density Ratio
ρ = Density
ρ* = Density with Throat location
Formula:
P0 / P0* = (1 / M) * [(2 / (γ + 1)) * (1 + ((γ - 1) / 2) * M2)]((γ+1) / (2*(γ-1)))
Where,
P0 / P0* = Fanno Flow Stagnation Pressure Ratio
P0 = Stagnation Pressure
P0* = Stagnation Pressure with Throat location
Formula:
V / V* = M / √((2 / (γ + 1)) * (1 + ((γ - 1) / 2) * M2))
Where,
V / V* = Fanno Flow Velocity Ratio
V = Velocity
V* = Velocity with Throat location